How to eliminate: "Automatic arrangement of pipe feeds not possible - change pipe feeds route or H/C Zone parameters or arrange pipe feeds manually"

Iš HelpSystem.
(Nukreipta iš HelpRedirectPageHS16)
Pereiti į navigaciją Jump to search


Produktas InstalSystem 5
Straipsnio tipas TYPICAL PROBLEM
Turinys aktualus versijai IS 5.0 Beta 28


Problem description

Problems associated with automatic generation of pipe feeds using the Pajungimų zona tool are diagnosed by means of the following message:

  • Nėra galimybės automatiškai pakloti jungtis- pakeisk pajungimo trasa/PŠ/V zonos parametrus arba paklok rankiniu būdu.

The message informs that pipe feeds could not be generated automatically by means of the Pajungimų zona tool, due to the following reasons:

  • specified or automatically sized arrangement spacings are too large,
  • manner of component crossing Pajungimų zona is inappropriate (for the algorithm of automatic pipe feed arrangement),
  • number of component crossings Pajungimų zona is too large,
  • Pajungimų zona components are located too close to each other,
  • width of the strip within which Pajungimų zona generates pipe feeds is too small or too large (reaches beyond the borders of the heating zone).

Solution

  • Specify smaller pipe feed arrangement spacing.


  • Change manner of Pajungimų zona component arrangement.


  • Increase width of Pajungimų zona component arrangement area.


  • Draw pipe feeds manually.

Depending on design circumstances, or when pipe feeds cannot be generated automatically, the tool for manual arrangement of pipe feeds can be used.
Daugiau informacijos: Manual pipe feeds editing.