How to eliminate: "Automatic arrangement of pipe feeds not possible - change pipe feeds route or H/C Zone parameters or arrange pipe feeds manually"
(Nukreipta iš HelpRedirectPageHS 16)
| Produktas | InstalSystem 5 |
| Straipsnio tipas | TYPICAL PROBLEM |
| Turinys aktualus versijai | IS 5.0 Beta 28 |
Problem description
Problems associated with automatic generation of pipe feeds using the Pajungimų zona tool are diagnosed by means of the following message:
- Nėra galimybės automatiškai pakloti jungtis- pakeisk pajungimo trasa/PŠ/V zonos parametrus arba paklok rankiniu būdu.
The message informs that pipe feeds could not be generated automatically by means of the Pajungimų zona tool, due to the following reasons:
- specified or automatically sized arrangement spacings are too large,
- manner of component crossing Pajungimų zona is inappropriate (for the algorithm of automatic pipe feed arrangement),
- number of component crossings Pajungimų zona is too large,
- Pajungimų zona components are located too close to each other,
- width of the strip within which Pajungimų zona generates pipe feeds is too small or too large (reaches beyond the borders of the heating zone).
Solution
- Specify smaller pipe feed arrangement spacing.
- Change manner of Pajungimų zona component arrangement.
- Increase width of Pajungimų zona component arrangement area.
- Draw pipe feeds manually.
Depending on design circumstances, or when pipe feeds cannot be generated automatically, the tool for manual arrangement of pipe feeds can be used.
Daugiau informacijos: Manual pipe feeds editing.